Unit Product Weight: 1 lbs
UPC: 895916000028
- The Sanitizer Wand kills up to 99% of bacteria and viruses
- Also fights unwanted odors and allergens like mold and dust mites
- UV-C is natural so you don't have to use harmful chemicals to kill germs.
- UV-C light technology is used in hospitals to sanitize surfaces and kill germs.
- Disinfection of a surfaces can be achieved by holding the Sanitizer Wand over a surface for 20 seconds at a distance of approximately 1-2 inches
Model Number: LW18
Weight: 1 pound (without batteries)
Dimensions: 24.5 in. W X 5 in. D X 2 in. H
Germicidal Lamp: 6 W DC lamp
Power Supply: 4 AA batteries (Not included)
Power Adapter Cord Length: 6 ft.
What is UV-C?
UV-C is part of the ultra-violet light spectrum that is filtered out by the earth's atmosphere. The "C" stands for the particular frequency of UV light that kills germs.
Why is UV-C so effective at destroying germs?
UV-C light is highly effective at penetrating thin-walled germs like viruses and bacteria. The light alters the genetic structure of the germs and they die.
Why is UV-C used in hospitals to sanitize?
Hospitals use the UV-C light technology to kill germs in the air and on surfaces. UV-C has been proven to kill germs that cause: influenza, strep throat, colds, staph infections and tuberculosis.
Is this new technology?
No. UV-C has been used to kill germs for almost 100 years. The first usage was in France in 1909 to disinfect their water system. This technology is still used today in hospitals, commercial buildings and custom homes to kill germs.
Where should I use the product?
Here is a list of ideas of where you can use the Sanitizer Wand. This list is NOT complete.
- Bedding
- Kitchen Counter
- Kitchen Sink
- Personal Items (hair brush, toothbrush, makeup brushes)
- Computer Keyboard and Mouse
- Bathroom Areas (sink, toilet, shower, bath tub)
- Shoes
- Silverware
- Furniture
No, the Sanitizer Wand is rated at 6,000 to 8,000 hours of use. If you were to use the UV-C Sanitizer Wand two hours per week, the wand bulb would last approximately seventy-six years.

Breathing clean air is very important to healthy living. Up until a short time ago, if you wanted to purify the air in your house you used a traditional forced air system that filtered out airborne germs with a multi-layered system, or a filter made out of carbon.
This method worked fine up to the point where the filter couldn't handle the amount of particles it was expected to remove from the air. Other drawbacks were that they were difficult to maintain and their operating expense was high due to the cost of replacement filters.
UV-C air sanitizers operate in a way that's unlike any other air purification technique. Rather than try to block every single contaminant in the air, UV-C sanitizers simply destroy the microorganism and cause it to be ineffective.
This approach is both simpler to keep up with as well as easier to maintain. Rather than trying to gather and dispose of harmful particles by buying expensive filters, a UV-C air sanitizer uses the sanitizing power of ultraviolet light.
Benefits of UV-C Air Sanitizers:
- Kills Over 99.9% of Airborne Bacteria: Unlike traditional air purifiers which become less effective as their filters get full and over worked, UV air sanitizers kill over 99.9% of the bacteria in the air.
- Odor Fighting: UV-C air sanitizers also help to reduce the odors in the air. Whether it's odors caused by pets, smoking, mildew or mold, ultraviolet light has the air cleaning power to make your house smell clean and fresh.
- Kills Mold: One of the ways UV-C air sanitizers fight mold and mildew smells is by actually stopping them from growing. The UV rays of their special light bulb kills mold spores at a micro organic level.
- Quietness: Traditional air purifiers use forced air induction and utilize noisy fans to create air movement. UV-C air sanitizers operate with only UV light. Amazingly, even small ultraviolet air sanitizers are able to process over 1000 cubic feet of air per hour.
Benefits of Ultrasonic Humidifiers:
They produce a warm or cool mist by using a metal diaphragm vibrating at high-frequency. The sound vibrations propel moisture into the air. The water molecules that are produced are extremely small, about one micron in diameter. The mist is almost immediately absorbed into the air. Keep the air from getting dry and stuffy and enjoy a better night's sleep with an Ultrasonic Humidifier.
- Bed mattresses, quilts, pillows: Vacuum the mattress first. Hold UV-C Sanitizer Wand approximately 1 inch above the surface and move the UV-C Sanitizer Wand over a 12 inch area for 20 seconds. Continue until the entire desired surface is covered.
- Animal mattresses and enclosure. Refer to Number 1 for directions.
- Personal hygiene items: Expose items such as personal razors, brushes combs and other personal hygiene implements at close range for a minimum of 10 seconds.
- Kitchen utensil Hold the wand at close range, exposing knives, utensils, chopping boards for a minimum of 10 seconds. Use away from water sources.
- Bathroom Germs and Odor Hold the wand approximately 2 inches above the surface of the toilet seat or sink and slowly move the wand sideways over the entire surface for a total of 20 seconds. Be careful not to immerse the wand in water
- Shoes Expose once a week at close range for five minutes to help kill germs that cause odors. Expose the soles of your shoes more frequently - the soles are the major source of bringing bacteria into the home!
- Computers, Doorknobs, Telephones, etc.: Expose at a distance of 1 inch for approximately 10 seconds.
- Sanitizing Tip: Effective sanitizing can generally be achieved in 20 seconds at a distance of approximately 1 inch
- Do not use outdoors or on wet surfaces.
- Do not allow to be used as a toy. Close attention is necessary when used by or near children or pets.
- Use only as described in this manual.
- If appliance is not working as it should, has been dropped, damaged, left outdoors or dropped in water, return it to the manufacturer.
- Do no handle plug or appliance with wet hands.
- Remove batteries before any routine cleaning or maintenance.
- Leaks from battery cells can occur under extreme conditions. If the liquid gets on the skin 1 wash quickly with soap and water or 2 neutralize with a mild acid such as lemon juice or vinegar. If the liquid gets into the eyes, flush them immediately with clean water for a minimum of 10 minutes. Seek medical attention.
- Children cannot recognize the hazards associated with the usage of electrical appliances. For this reason, always supervise children when they are near the product.
- Use only AA batteries.
Ultraviolet light is emitted from the bulb when the unit is electrified. eye injury or skin irritation could result. do not operate the unit if the enclosure is damaged. do not expose skin or eyes to within 3-inches of the uv-c sanitizer wand for a period of 3 hours or more. skin or eye irritation could result.
If this product should become defective within the warranty period, Guardian Technologies LLC will repair or replace any defective parts free of charge. The complete machine must be delivered pre-paid to any authorized Guardian Technologies LLC warranty service center. Please include complete information on the problem, date of purchase, copy of original sales receipt and your name, address and telephone number. If you are not near a warranty center, call the factory for assistance in the US and Canada at 1.866.603.5900. Use only genuine Guardian Technologies replacement parts.
The warranty does not include unusual wear, damage resulting from accident, or unreasonable use of the product. This warranty does not cover bulbs. This warranty does not cover unauthorized repairs. This warranty gives you specific legal rights and you may also have other rights (other rights may vary from state to state in the U.S.A.). Guardian Technologies LLC consider the registration process important to ensuring superior service to their customers, however submitting the warranty card to Guardian Technologies LLC is optional and does not affect your rights to utilize this warranty according to the conditions stated above. If you have any questions or comments about their product call toll free at 1.866.603.5900 or send comments to:
ATTN: Customer Service
Guardian Technologies LLC
7700 St Clair Avenue
Mentor, Ohio 44060







